Simple soundproofing (acoustic comfort) with Fastmount SL-FB + Knauf

Decorative cladding that is removable and improves the acoustic comfort of the room (on its own it is not certified soundproofing). Mounted on metal framing and concealed clips Fastmount SL-FB. Optionally, you can boost performance by adding an acoustic sheet/board such as Danofon between the wall and the cladding.

Precision: SL-FB compatibility depends on the exact dimensions of the channel/omega profile (opening 35–35.75 mm; depth 15.75–16.5 mm). Check on site (dry test) or use Stratlock rails. Danofon improves the assembly, but the final insulation depends on the whole wall build-up.

What you will achieve

  • Acoustic comfort: less reverberation and better sound perception inside the room.
  • Premium finish: decorative panels (grooved MDF, acoustic cores, etc.) with concealed fixing and precise alignment.
  • Easy maintenance: panels that can be removed to access the services behind the cladding.

Important: this system on its own is not a sound insulation solution between dwellings. If you need certified dB between rooms, add Danofon and design the complete build-up.

Materials and components

  • Female clip: Fastmount SL-FB (or SL-FB-FR if you require a fire rating). It pushes into a galvanised channel/rail with an opening of 35.0–35.75 mm and a depth of 15.75–16.5 mm.
  • Male clip: SL-M18 (≈18 kg pull-out) or SL-M10 (≈10 kg), screwed to the back of the panel.
  • Metal framing: plasterboard system Knauf (channels/studs) or a 35 mm Omega-type profile that is compatible (check the actual opening). Alternative: Stratlock rails.
  • Upgrade option (insulation): Danofon bonded or mechanically fixed to the existing wall (before the framing/cladding).
  • Tools: centring tool CP-01ST, drill and fixings, screwdriver, laser level, saw, PPE.

SL-FB compatibility with the profile

The SL-FB pushes into a galvanised channel with an opening of 35–35.75 mm and a depth of 15.75–16.5 mm. In plasterboard systems:

  1. Use an auxiliary 35 mm Omega-type profile whose opening meets those dimensions, or
  2. Use Stratlock rails for guaranteed tolerances and 360° adjustment.

Not all standard C studs/tracks have that opening. Always measure with a calliper.

Assembly diagram

  1. Existing wall
  2. (Optional) Danofon bonded/fixed and sealed around the perimeter
  3. Knauf channels/studs or 35 mm Omega (compatible), anchored to the wall
  4. SL-FB pushed into the channel
  5. Marking with centring tool CP-01ST on the panel
  6. SL-M18/SL-M10 screwed to the back of the panel
  7. Hanging and double “click” for final fixing and adjustment

Step by step (removable direct wall lining)

  1. Setting out and preparation
    Check that the substrate is flat and sound. Mark out the framing lines and fixing points. If you are upgrading the insulation, cut and offer up the Danofon.
  2. Anchoring the framing
    Fix the channels/omegas to the wall with suitable plugs and screws (400–600 mm spacing depending on calculation/weight). Check that the channel has an opening of 35–35.75 mm (dry test with an SL-FB).
  3. Fit Danofon (optional)
    Bond or mechanically fix the acoustic sheet/panel and seal perimeters and junctions to avoid sound bridges.
  4. Insert the female clips (SL-FB)
    Push each SL-FB into the compatible channel/omega. Space them evenly according to the setting-out.
  5. Mark the pairs on the panel
    Offer up the panel and use the CP-01ST to transfer the centres from the SL-FB clips to the back of the panel.
  6. Fit the male clips
    Screw SL-M18 (heavy panel) or SL-M10 (light panel) to the back of the panel to suit the material (MDF, plywood, acoustic composite).
  7. Hang and fine-tune
    First “click” to hang, adjust (alignment/gaps) and press until the second “click” for final fixing.
  8. Finishing
    Seal around the perimeter with acoustic sealant/silicone where appropriate. Check sockets and service penetrations.

Acoustic performance: comfort vs. insulation

This system improves acoustic comfort (it reduces internal reflections). For sound insulation between rooms (dB), you need a specific partition and sealing solution. Danofon can raise the overall result, but the final value depends on the whole assembly (base wall + sheets + cavity + panel). If you are targeting a specific dB figure, request an acoustic calculation and a technical report.

Frequently asked questions

Does this system soundproof between dwellings?

Not on its own. It improves the acoustic comfort of the room. For insulation, add Danofon and design the whole build-up.

Which metal profile do I need?

A channel/omega with an opening of 35–35.75 mm to take the SL-FB. If it does not, use Stratlock rails.

Which male clip should I use?

SL-M18 for heavy panels, SL-M10 for light ones. Size the number of fixing points for load and safety.

Can I achieve a fire rating?

For fire requirements, use components and panels that have been tested. A version is available: SL-FB-FR. Check local regulations.

Purchase and advice

Accuracy note: always validate profile tolerances (opening and depth) and material compatibility on site. Acoustic results depend on the whole assembly. If you need certified dB values, insist on a test of the complete solution and a specific calculation.